Sign Up to our social questions and Answers Engine to ask questions, answer people’s questions, and connect with other people.
Login to our social questions & Answers Engine to ask questions answer people’s questions & connect with other people.
Lost your password? Please enter your email address. You will receive a link and will create a new password via email.
Please briefly explain why you feel this question should be reported.
Please briefly explain why you feel this answer should be reported.
Please briefly explain why you feel this user should be reported.
Resolved the problem of the ”cuda driver version is insufficient for cuda runtime version”.
The cause: When you choose (using the nvidia-settings utility) the built-in Intel GPU and run the deviceQuery script, you encounter this problem, which is associated with the choice GPU mode (Performance/Power Saving Mode). Additionally, libcuda also causes this error. Even when the versions given bRead more
The cause:
When you choose (using the nvidia-settings utility) the built-in Intel GPU and run the deviceQuery script, you encounter this problem, which is associated with the choice GPU mode (Performance/Power Saving Mode).
Additionally, libcuda also causes this error. Even when the versions given by nvidia-smi precisely match, is not discovered. This library is a component of the nvidia-drivers package (x11-drivers/nvidia-drivers on Gentoo, nvidia-driver-latest-cuda-libs on CentOS).
Solution:
You can do as the following suggestion to solve this error:
Let’s access to this developer site to install the driver again and it will run well.
http://developer.nvidia.com/object/cuda_3_1_downloads.html#MacOS
Or you can set up the most recent driver or utilize an outdated toolkit in order to compile your program.
See lessCreateprocess error=193, %1 is not a valid win32 application – simple solution when encountering the error.
The cause: You have got this error because of two reasons: You are trying to load a file that isn't an executable one. One of the executable's dependents, means that the DLLs are connected to the executable file, is having trouble in the process of loading. A mismatch between a 32 bit executable anRead more
The cause:
You have got this error because of two reasons:
Solution:
To solve this problem, you must supply an executable file to
CreateProcess
. You requireShellExecute
instead ofCreateProcess
in the case you want to be able to open any file with its related applications.Let’s use Dependency Walker’s profile mode to determine precisely what is incorrect happening for investigating purpose and get more information.
See lessWays to resolve the error – ora 01438 value larger than specified precision allowed for this column.
The cause: This error happens because for datatype number (2,2), you cannot update with a number higher than 1. The reason is that the first parameter (in this case is 2) is the number of digits in the decimal component and the first parameter is the total number of digits in the number. Solution: YRead more
The cause:
This error happens because for datatype number (2,2), you cannot update with a number higher than 1. The reason is that the first parameter (in this case is 2) is the number of digits in the decimal component and the first parameter is the total number of digits in the number.
Solution:
You only can update numbers which are
< 1
, for example: 0.12, 0.95, 0.85,….Let’s read this NUMBER Datatype to check number databse.
See lessSimple solutions for the ”ora 00932 inconsistent datatypes expected got clob” error.
The cause: You have got the ''ora 00932 inconsistent datatypes expected got clob'' error due to you are not allowed to place a CLOB in the WHERE clause. The reason is that big objects (for example, LOBs) are not encouraged in the conditions of comparison, so the error occurs. Solution: For comparisoRead more
The cause:
You have got the ”ora 00932 inconsistent datatypes expected got clob” error due to you are not allowed to place a CLOB in the WHERE clause. The reason is that big objects (for example, LOBs) are not encouraged in the conditions of comparison, so the error occurs.
Solution:
For comparisons on CLOB data, PL/SQL programs are great solution for you.
In the case your values are not enough 4k, let’s use:
If you do as my above suggestions, you will solve your error successfully. Wish you all the best!
See lessResolved the problem of the ”object cannot be cast from dbnull to other types”.
The cause: After researching your problem for hours, I found that the parameter of your output is returning a value of DBNull. This is the reason why you have got the: ''object cannot be cast from dbnull to other types” error. Solution: The easiest solution for this error is adding a check for DBNulRead more
The cause:
After researching your problem for hours, I found that the parameter of your output is returning a value of DBNull. This is the reason why you have got the: ”object cannot be cast from dbnull to other types” error.
Solution:
The easiest solution for this error is adding a check for DBNull value as the following:
Another way that is equally effective is using the
Convert.IsDBNull
method:Learn how to fix error: nvcc fatal : cannot find compiler ‘cl.exe’ in path.
The cause: The compiler of Microsoft's C/C++ is cl.exe. You haven't installed it somewhere that the command line can locate it, this is the problem. Solution: To solve this problem, you have to make sure that the folder including the "cl.exe" file is added into the path of environment variable. YouRead more
The cause:
The compiler of Microsoft’s C/C++ is
cl.exe
. You haven’t installed it somewhere that the command line can locate it, this is the problem.Solution:
To solve this problem, you have to make sure that the folder including the “cl.exe” file is added into the path of environment variable. You can do as the following suggestion:
Another way is following these steps: access to My Computer -> Properties -> Advanced System Settings -> Environment Variables.
Find “PATH” in the list and add the previously mentioned path there (or even if whatever is the position of your cl.exe).
See lessLearn how to fix error: no instance of overloaded function matches the argument list.
The cause: Although you a constructor that has two parameters and a default one, there is not a constructor for your String type that just accepts one argument. Therefore, the error happens. Solution: To solve this problem, you need to specify a constructor which accepts an unique parameter and initRead more
The cause:
Although you a constructor that has two parameters and a default one, there is not a constructor for your String type that just accepts one argument. Therefore, the error happens.
Solution:
Copy
andConcat
functions which you give an unique parameter into a String object as the following:How to fix “no enclosing instance of type is accessible”.
The cause: From your program I found that the class of Thing was declared as a non-static inner class. This implies that it must be connected to a Hello class instance. You are attempting to build a Thing instance from a static context in your code. However, static methods did not have permission toRead more
The cause:
From your program I found that the class of
Thing
was declared as a non-static inner class. This implies that it must be connected to aHello
class instance. You are attempting to build aThing
instance from a static context in your code. However, static methods did not have permission to access to a non-static inner class. This is the reason for your mistake.Solution:
See lessstatic class Thing
can solve your problem and help your program run well. A specificHello
instance must be in scope fornew Thing()
to work if you have specifiedThing
as an inner class, which is linked to a specific instance ofHello
by definition (even if you never use or refer to it). If you declare it as a static type rather than a dynamic class, it will become “nested”, and you do not need aHello
instance.Error: missing from-clause entry for table – how to solve it?
The cause: This error happens because your FROM or JOIN clauses do not include the gtab82 table. Another reason is that an alias name is used for a table but the WHERE clause does not include it. Solution: Only when you need to prefix a column with the table name because there are duplicate column nRead more
The cause:
This error happens because your FROM or JOIN clauses do not include the gtab82 table. Another reason is that an alias name is used for a table but the WHERE clause does not include it.
Solution:
Only when you need to prefix a column with the table name because there are duplicate column names in the connected tables and the table name is large or when the table is joined to itself should you use an alias for the table name. In your situation, VCustomer has an alias, but you only use it in the ON clause for unknown reasons. You had better check that section of your code.
How to solve ”mapping values are not allowed in this context”?
The cause: You get the ''mapping values not allowed in this context'' error because you cannot use a multiline plain scalar, like your include:false transitions, as the key to a mapping. Solution: After (:) in the value indicator, you need to put a space as the following: include: false transitions:Read more
The cause:
You get the ”mapping values not allowed in this context” error because you cannot use a multiline plain scalar, like your include:false transitions, as the key to a mapping.
Solution:
After (
:
) in the value indicator, you need to put a space as the following:Your multi-line scalar also need to be quoted:
Another way is putting the plain scalar on a line:
However, there’s one thing to keep in mind. Some libraries do not accept value indicators in a simple scalar form at all, even if they aren’t followed by a space.
See less